Series amplifiers are made for Funktion One by English amplifier designers and manufacturers Full Fat Audio (FFA). The four channel DSP models; Networking, four inputs and six outputs (four via amplifier channels and two via additional signal channels) and intuitive software offer great flexibility for both live and installation. The new F20Q is useful for powering distributed systems of small loudspeakers such as the F55 or F81.
The F80Q's new electronic design makes it especially suited to powering the Evo 6 and 7 range with exceptional audio quality.
All amplifiers utilise rugged switch modulation power supplies (SMPS) with Class D Pulse Width Modulation amplifier stages.
Features:
- High efficiency FFA Class D technology
- DSP card (4 channel models only)
- Rugged tour class Aluminium construction
- Lightweight
- Side chain TCA clip limiter
- Signal link connectors
- Hand built and designed in England
- New F20Q and F80Q now available
F20Q Four Channel Amplifier:
Output power (Watts RMS) per channel
8Ω - 250W; 4Ω - 500W; 2Ω - 1000W
F40Q Four Channel Amplifier:
Output power (Watts RMS) per channel
8Ω - 600W; 4Ω - 1000W
F60Q Four Channel Amplifier:
Output power (Watts RMS) per channel
8Ω - 800W; 4Ω - 1500W
F80Q Four Channel Amplifier:
Output power (Watts RMS) per channel
8Ω - 1000W; 4Ω - 2000W
Other FFA amplifiers can be supplied on request
Technical Specifications
Gain: 32dB
THD: Typical 0.05% @ 4Ohm, 1kHz THD+N
Frequency Response: 20Hz - 20kHz ±0.5dB
Controls: 40 point potentiometer per channel, power on switch
Indicators: signal green = -20dB, signal yellow = -3dB, red signal = clip, signal red protect = over current, low AC mains or 3 sec. mute on power up
Load Protection: DC on output, side chain TCA clip limiter circuit
Amplifier Protection: Short circuit, current overload, thermal shutdown, high frequency stability circuit
Audio Signal Inputs: Balanced Neutrik® Female XLR input connected Pin 1 - GND, Pin 2 - Hot, Pin 3 - Cold, XLR Male signal throughout each channel
Audio Signal Outputs: Neutrik® speakON each channel. Channels 1 & 3 output speakON utilises 2+ and 2- connection to allow use of 4 core loudspeaker cable for bi amp loudspeaker system, for example stage monitor system.
Power Requirement: 1 x Neutrik® 20A powerCON connector, 2 x 16A 240V VAC circuit. Power range 185V-240V AC
System Cooling: High CFM 80mm fan with proportional signal speed control. Rear to front airflow.
Dimensions: 483mm x 510mm x 88mm. Includes rear rack support. 19'' rack mount enclosure
Weight: 9kg (F40Q & F60Q); 12kg (F100-2)